SMSC LAN9312

DATASHEET

14.5.3

Switch Engine CSRs

This section details the switch engine related CSRs. These registers allow configuration and monitoring
of the various switch engine components including the ALR, VLAN, Port VID, and DIFFSERV tables.
A list of the general switch CSRs and their corresponding register numbers is included in

Table 14.12

.

14.5.3.1

Switch Engine ALR Command Register (SWE_ALR_CMD)

This register is used to manually read and write MAC addresses from/into the ALR table.

For a read access, the

Switch Engine ALR Read Data 0 Register (SWE_ALR_RD_DAT_0)

and

Switch

Engine ALR Read Data 1 Register (SWE_ALR_RD_DAT_1)

should be read following the setting of bit

1(Get First Entry) or bit 0(Get Next Entry) of this register.

For write access, the

Switch Engine ALR Write Data 0 Register (SWE_ALR_WR_DAT_0)

and

Switch

Engine ALR Write Data 1 Register (SWE_ALR_WR_DAT_1)

registers should first be written with the

MAC address, followed by the setting of bit 2(Make Entry) of this register. The Make Pending bit in the

Switch Engine ALR Command Status Register (SWE_ALR_CMD_STS)

register indicates when the

command is finished.

Refer to

Chapter 6, "Switch Fabric," on page 55

for more information.

Register #:

1800h

Size:

32 bits

BITS

DESCRIPTION

TYPE

DEFAULT

31:3

RESERVED

RO

-

2

Make Entry
When set, the contents of ALR_WR_DAT_0 and ALR_WR_DAT_1 are
written into the ALR table. The ALR logic determines the location where the
entry is written. This command can also be used to change or delete a
previously written or automatically learned entry. This bit has no affect when
written low. This bit must be cleared once the ALR Make command is
completed, which can be determined by the ALR Status bit in the

Switch

Engine ALR Command Status Register (SWE_ALR_CMD_STS)

register.

R/W

0b

1

Get First Entry
When set, the ALR read pointer is reset to the beginning of the ALR table
and the ALR table is searched for the first valid entry, which is loaded into
the ALR_RD_DAT_0 and ALR_RD_DAT_1 registers. The bit has no affect
when written low. This bit must be cleared after it is set.

R/W

0b

0

Get Next Entry
When set, the next valid entry in the ALR MAC address table is loaded into
the ALR_RD_DAT_0 and ALR_RD_DAT_1 registers. This bit has no affect
when written low. This bit must be cleared after it is set.

R/W

0b