High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface

Datasheet

SMSC LAN9312

399

Revision 1.4 (08-19-08)

DATASHEET

14.5.3.30

Switch Engine Port 0 Ingress Filtered Count Register (SWE_FILTERED_CNT_MII)

This register counts the number of packets filtered at ingress on Port 0(Host MAC). This count includes
packets filtered due to broadcast throttling but does not include packets dropped due to ingress rate
limiting (which are counted separately).

Register #:

1850h

Size:

32 bits

BITS

DESCRIPTION

TYPE

DEFAULT

31:0

Filtered
This field is a count of packets filtered at ingress and is cleared when read.

Note:

This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 481 hours.

RC

00000000h