Section 14.5.3.27, Switch engine ingress rate command status, Register (swe_ingrss_rate_cmd_sts) – SMSC LAN9312 User Manual

Page 396: Indicates, Switch, Datasheet

Advertising
background image

High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface

Datasheet

Revision 1.4 (08-19-08)

396

SMSC LAN9312

DATASHEET

14.5.3.27

Switch Engine Ingress Rate Command Status Register (SWE_INGRSS_RATE_CMD_STS)

This register indicates the current ingress rate command status.

Register #:

184Ch

Size:

32 bits

BITS

DESCRIPTION

TYPE

DEFAULT

31:1

RESERVED

RO

-

0

Operation Pending
When set, indicates that the read or write command is taking place. This bit
is cleared once the command has finished.

RO

SC

0b