Switch engine alr read data 1, Register (swe_alr_rd_dat_1), Switch engine alr read data 1 register – SMSC LAN9312 User Manual

Page 371: Swe_alr_rd_dat_1), Can be stor, Section 14.5.3.5, Switch, Engine alr read data 1 register (swe_alr_rd_dat_1), Datasheet

Advertising
background image

High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface

Datasheet

SMSC LAN9312

371

Revision 1.4 (08-19-08)

DATASHEET

14.5.3.5

Switch Engine ALR Read Data 1 Register (SWE_ALR_RD_DAT_1)

This register is used in conjunction with the

Switch Engine ALR Read Data 0 Register

(SWE_ALR_RD_DAT_0)

to read the ALR table. It contains the last 32 bits of the ALR entry and is

loaded via the Get First Entry or Get Next Entry commands in the

Switch Engine ALR Command

Register (SWE_ALR_CMD)

. This register is only valid when either of the Valid or End of Table bits are

set.

Register #:

1806h

Size:

32 bits

BITS

DESCRIPTION

TYPE

DEFAULT

31:25

RESERVED

RO

-

24

Valid
This bit is cleared when the Get First Entry or Get Next Entry bits of the

Switch Engine ALR Command Register (SWE_ALR_CMD)

are written. This

bit is set when a valid entry is found in the ALR table. This bit stays cleared
when the top of the ALR table is reached without finding an entry.

RO

0b

23

End of Table
This bit indicates that the end of the ALR table has been reached and further
Get Next Entry commands are not required.

Note:

The Valid bit may or may not be set when the end of the table is
reached.

RO

0b

22

Static
Indicates that this entry will not be removed by the aging process. When this
bit is cleared, this entry will be automatically removed after 5 to 10 minutes
of inactivity. Inactivity is defined as no packets being received with a source
address that matches this MAC address.

RO

0b

21

Filter
When set, indicates that packets with a destination address that matches
this MAC address will be filtered.

RO

0b

20:19

Priority
These bits indicate the priority that is used for packets with a destination
address that matches this MAC address. This priority is only used if the
Static bit of this register is set, and the DA Highest Priority (bit 5) in the

Switch Engine Global Ingress Configuration Register
(SWE_GLOBAL_INGRSS_CFG)

register is set.

RO

00b

Advertising