Inverter motor control register 0 – Samsung S3F401F User Manual

Page 105

Advertising
background image

INVERTER MOTOR CONTROLLER (IMC)

S3F401F_UM_REV1.00

6-26

Inverter Motor Control Register 0

IMCON0 (0x000)

Access: Read/Write

31 30

29

28 27

26

25

24

DBGEN

SYNCSEL[27:26]

P25

R/W-0 R/W-0

R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0

23 22

21

20 19

18

17

16

NUMSKIP[23:21]

IMCLKSEL[18:16]

R/W-0 R/W-0

R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0

15 14

13

12

11 10 9 8

PWMOUTEN

PWMOUTOFFEN

PWMOFFEN

IMFILTER [10:8]

R/W-0 R/W-0

R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0

7 6

5

4 3

2

1

0

ESELPWMOFF6[7:6]

PWMPOLD

PWMPOLU

PWMSWAP

WMODE

IMMODE

IMEN

R/W-0 R/W-0

R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0

W: Write

R: Read

-0: 0 After reset

-1: 1 After reset

-U: Undefined after reset

IMEN

Inverter Motor Block Enable/Disable Control Bit

0 = Disable IMC Block

Æ IMCNT is cleared to 0 automatically

1 = Enable IMC Block

IMMODE

Inverter Motor Mode Selection Bit

0 = Tri-angular shape

1 = Saw-tooth shape

This bit can

be changed

only when

IMCON.0

is

0

.

If this bit is set to ‘1’, comparison with ‘0’ is no effect (INT_ZEROx will not be occurred.)

WMODE

Write Mode Selection of Compare Register

0 = Immediate write

1 = Synchronous write

Note: In the synchronous write, if IMCNT equals to 0 or TOPCMP, compare registers including
dead-time compare register which are written are updated simultaneously. Synchronous write is related
to NUMSKIP. For example, if NUMSKIP is 30, synchronous write happens only one time in every 30
times. ADC trigger signal is the same situation.

PWMSWAP

Swapping of PWMxUx and PWMxDx

0 = No Swap

1 = Swap

Note: This bit can be changed only when IMCON.0 is 0.

Advertising