INVERTER MOTOR CONTROLLER (IMC)

S3F401F_UM_REV1.00

6-34

Inverter Motor Status Register

IMSTATUS (0x008)

Access: Read/Write

31 30 29 28 27 26 25 24

R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0

23 22 21 20 19 18 17 16

R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0

15 14 13 12 11 10 9 8

R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0

7 6 5 4 3 2 1 0

UPDOWNSTAT

FAULTSTAT

R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0 R/W-0

W: Write

R: Read

-0: 0 After reset

-1: 1 After reset

-U: Undefined after reset

FAULTSTAT

Status of PWM Output Signal

0 = Normal operating

1 = High-Z (Inverter motor block is operating but the status of PWM signal is High-Z.

This bit can be set by fault detection of PWMxOFF pin or IMCON0.14.)

Note: If this bit is written to 0 and IMCON0.14 is 0, inverter motor control signal is output to PWM output.

UPDOWNSTAT Status of PWM Counter

0 = Up counting

Æ This bit is always ‘0’ in the saw-tooth mode.

1 = Down counting