Adc start signal select register – Samsung S3F401F User Manual

Page 114

Advertising
background image

S3F401F_UM_REV1.00

INVERTER MOTOR CONTROLLER (IMC)

6-35

ADC Start Signal Select Register

ADCSTARETSEL (0x00C) Access: Read/Write

31 30 29 28

27

26

25 24

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0 R/W-0

R/W-0

R/W-0

23 22 21 20

19

18

17 16

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0 R/W-0

R/W-0

R/W-0

15 14 13 12

11

10

9

8

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0 R/W-0

R/W-0

R/W-0

7 6 5 4

3

2

1 0

ADCCMPF0SEL

ADCCMPR0SEL

0SEL

TOPCMPSEL

R/W-0 R/W-0 R/W-0 R/W-0

R/W-0 R/W-0

R/W-0

R/W-0

W: Write

R: Read

-0: 0 After reset

-1: 1 After reset

-U: Undefined after reset

TOPCMPSEL

Enable ADC Start Trigger Signal by TOPCMP Match

0 = Not selected

1 = Selected

0SEL

Enable ADC Start Trigger Signal by Counter Zero Match

0 = Not selected

1 = Selected

ADCCMPR0SEL Enable ADC Start Trigger Signal by ADCCMPR0 Match

0 = Not selected

1 = Selected

ADCCMPF0SEL Enable ADC Start Trigger Signal by ADCCMPF0 Match

0 = Not selected

1 = Selected

ADCCMPR1SEL Enable ADC Start Trigger Signal by ADCCMPR1 Match

0 = Not selected

1 = Selected

ADCCMPF1SEL Enable ADC Start Trigger Signal by ADCCMPF1 Match

0 = Not selected

1 = Selected

ADCCMPR2SEL Enable ADC Start Trigger Signal by ADCCMPR2 Match

0 = Not selected

1 = Selected

Advertising