Phase signal generation, 1 tri-angular wave (immode = 0) – Samsung S3F401F User Manual

Page 84

Advertising
background image

S3F401F_UM_REV1.00

INVERTER MOTOR CONTROLLER (IMC)

6-5

4. PHASE SIGNAL GENERATION

4.1 TRI-ANGULAR WAVE (IMMODE = 0)

PWMSWAP = 0, PWMPOLU = 0 (Low start), PWMPOLD = 1 (High start)

These phase signals are used when switches of UP side and DOWN side are high active in inverter motor
application. That means one pair switches of UP side and DOWN side don’t have condition with high active at the
same time. So dead time is inserted the following that.

PCCMPR

PBCMPR

(Can be used by ADC trigger signal)

TOPCMP

PACMPF

ADCCMPF0

PACMPR

ADCCMPR0

TOPCMP

ADCCMPF1

PBCMPF

ADCCMPF2

PCCMPF

ADCCMPR1

ADCCMPR2

Figure 6-4. Inverter Motor Controller (IMC) Signal generation (Tri-angular wave)