External interrupt filter control register – Samsung S3F401F User Manual

Page 185

Advertising
background image

I/O PORTS

S3F401F_UM_REV1.00

8-36

External Interrupt Filter Control Register

EXTINTF0 (0x058) Access: Read/Write

31

30 29 28

27

26

25

24

EXTINTF3EN

EXTINT3SEL[28:24]

R/W-0

R/W-0 R/W-0 R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

23

22 21 20

19

18

17

16

EXTINTF2EN

EXTINT2SEL[20:16]

R/W-0

R/W-0 R/W-0 R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

15

14 13 12

11

10

9 8

EXTINTF1EN

EXTINT1SEL[12:8]

R/W-0

R/W-0 R/W-0 R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

7

6 5 4

3

2

1

0

EXTINTF0EN

EXTINT0SEL[4:0]

R/W-0

R/W-0 R/W-0 R/W-0

R/W-0 R/W-0 R/W-0 R/W-0

W: Write

R: Read

-0: 0 After reset

-1: 1 After reset

-U: Undefined after reset

EXTINT0SEL External Interrupt with Filter Selection Field

00000 = INT0

01000 = INT8

10000 = INT16

11000 = INT24

00001 = INT1

01001 = INT9

10001 = INT17

11001 = INT25

00010 = INT2

01010 = INT10

10010 = INT18

11010 = INT26

00011 = INT3

01011 = INT11

10011 = INT19

11011 = INT27

00100 = INT4

01100 = INT12

10100 = INT20

11100 = INT28

00101 = INT5

01101 = INT13

10101 = INT21

11101 = INT29

00110 = INT6

01110 = INT14

10110 = INT22

11110 = INT30

00111 = INT7

01111 = INT15

10111 = INT23

EXTINTF0EN External Interrupt Filter Selection Bit

0 = Disable

1 = Enable

EXTINT1SEL External Interrupt with Filter Selection Field

00000 = INT0

01000 = INT8

10000 = INT16

11000 = INT24

00001 = INT1

01001 = INT9

10001 = INT17

11001 = INT25

00010 = INT2

01010 = INT10

10010 = INT18

11010 = INT26

00011 = INT3

01011 = INT11

10011 = INT19

11011 = INT27

00100 = INT4

01100 = INT12

10100 = INT20

11100 = INT28

00101 = INT5

01101 = INT13

10101 = INT21

11101 = INT29

00110 = INT6

01110 = INT14

10110 = INT22

11110 = INT30

00111 = INT7

01111 = INT15

10111 = INT23

Advertising