S3F401F_UM_REV1.00

TIMER

11-11

Timer Pre-Scale Register

TPRE (0x004)

Access: Read/Write

31

30 29 28 27 26 25

24

R/W-0 R/W-0 R/W-0

R/W-0

R/W-0 R/W-0 R/W-0

R/W-0

23

22 21 20 19 18 17

16

R/W-0 R/W-0 R/W-0

R/W-0

R/W-0 R/W-0 R/W-0

R/W-0

15

14 13 12 11 10 9

8

R/W-0 R/W-0 R/W-0

R/W-0

R/W-0 R/W-0 R/W-0

R/W-0

7

6 5 4 3 2 1

0

PRESCALE[7:0]

R/W-1 R/W-1 R/W-1

R/W-1

R/W-1 R/W-1 R/W-1

R/W-1

W: Write

R: Read

-0: 0 After reset

-1: 1 After reset

-U: Undefined after reset

Pre-scale Value for Timer

PRESCALE

0x00~ 0xFF

NOTE

The PRESCALE register can be changed only when TEN is set to 0, in other words timer should be stop.

Timer input clock frequency (t

CLK

) = PCLK / (pre-scale value + 1)

pre-scale value = 0 – 255

For example)

PCLK = 90MHz

PRESCALE = 11