TIMER

S3F401F_UM_REV1.00

11-14

Timer Count Register

TCNT (0x010) Access: Read Only

31

30 29 28 27 26 25

24

R-0

R-0 R-0 R-0 R-0 R-0 R-0

R-0

23

22 21 20 19 18 17

16

R-0

R-0 R-0 R-0 R-0 R-0 R-0

R-0

15

14 13 12 11 10 9

8

CV [15:8]

R-0

R-0 R-0 R-0 R-0 R-0 R-0

R-0

7

6 5 4 3 2 1

0

CV [7:0]

R-0

R-0 R-0 R-0 R-0 R-0 R-0

R-0

W: Write

R: Read

-0: 0 After reset

-1: 1 After reset

-U: Undefined after reset

The current timer's count value during the normal operation

CV

0x0000 ~ 0xFFFF

IMPORTANT
NOTE

The following registers (TPRE, TDAT and TPDAT) load the setting value by CL bit signal (timer counter
clear).