500/2500 Line Disconnect

Feature implementation

Task summary list

The following is a summary of the tasks in this section:

1.

"LD 10 – Allow Line Disconnect Tone for analog (500/2500-type) ports."
(page 124)

2.

"LD 15 – Specify the dial tone timer for analog (500/2500-type) ports."
(page 124)

Note: Feature implementation is the same for both 500/2500 Line
Disconnect and 500/2500 Line Disconnect for Outgoing Calls.

LD 10 - Allow Line Disconnect Tone for analog (500/2500-type) ports.

Prompt

Response

Description

REQ:

NEW CHG

New, or change.

TYPE:

500

Telephone type.

TN

Terminal Number

l s c u

Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.

c u

Format for Small System, Media Gateway 1000B, and Media
Gateway 1000T, where c = card and u = unit.

CLS

(LDTD) LDTA
(WTA) WTD

(Deny) allow Line Disconnect Tone.
(Allow) deny Warning Tone.

LD 15 - Specify the dial tone timer for analog (500/2500-type) ports.

Prompt

Response

Description

REQ:

NEW CHG

New, or change.

TYPE:

TIM

Timers.

CUST

Customer number

0-99

Range for Large System and CS 1000E system.

0-31

Range for Small System, Media Gateway 1000B, and Media
Gateway 1000T.

...

- LDTT

2-(6)-30

Line Disconnect Tone timer for the 500/2500 port, in seconds.

Feature operation

No specific operating procedures are required to use this feature.