Nortel Networks NN43001-106 User Manual

Page 353

Advertising
background image

Feature implementation

353

Prompt

Response

Description

- ITH2

2-255

Visual indication threshold 2 (number of calls in queue ˇ

S

ITH2 but < ITH3).

- ITH3

3-255

Visual indication threshold 3 (number of calls in queue ˇ

S

ITH3).

LD 12 - Enable/disable supervisory console Silent Observe.

Prompt

Response

Description

REQ

CHG

Change existing data.

TYPE

2250

Attendant console type.

TN

l s c u

Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.

c u

Format for Small System and Media Gateway 1000B where
c = card and u = unit.

KEY

0 BVR

Add Busy Verify key (key 0) for silent observation.

LD 12 - Enable/disable supervisory console for M2250 consoles with Enhanced Busy Lamp
Field and Silent Observe.

Prompt

Response

Description

REQ

CHG

Change existing data.

TYPE

2250

Attendant console type.

TN

l s c u

Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.

c u

Format for Small System and Media Gateway 1000B where
c = card and u = unit.

EBLF

(BLFD) BLFA

(Deny) allow Enhanced Busy Lamp Field.

KEY

0 BVR

Add Busy Verify key (key 0) for silent observation.

LD 15 - Enable/disable an M2250 console using Trunk Group Busy keys as status keys.

Prompt

Response

Description

REQ:

CHG

Change existing data.

TYPE:

ATT_DATA

Attendant console options.

CUST

Customer number

0-99

Range for Large System and CS 1000E system.

0-31

Range for Small System and Media Gateway 1000B.

- OPT

(XTG) ITG

Exclude/include Trunk Group Busy Indication.

Nortel Communication Server 1000

Features and Services - Book 1 of 6 (A to B)

NN43001-106

01.04

Standard

Release 5.0

27 July 2007

Copyright © 2007, Nortel Networks

.