Feature implementation

563

Prompt

Response

Description

BTDD

(BOTH)
INC

Busy Tone Detection Direction:
Both Incoming and outgoing calls (default).
Incoming calls only.

FREQ_0

350 - 655

Frequency of Busy Tone for Frequency 0 of a dual Busy Tone
Detection to be detected in Hz. Valid entries are in multiples
of 5Hz.

FREQ_1

350 - 655

Frequency of Busy Tone for Frequency 1 of a dual Busy Tone
Detection to be detected in Hz. Valid entries are in multiples
of 5Hz.

For a single busy tone FREQ_1 must be set the same as
FREQ_0.

FDLT

10 - 315

Frequency Delta. FDLT gives the tolerance of the tone to be
detected in +/- hertz. Valid entries are in multiples of 5Hz.

For dual Busy Tone Detection on the NT5D31 card, the same
maximum and minimum levels apply to both tones.

FLVL_MAX

0 - 15

Maximum Frequency Tone level to be detected. Valid entries
are in multiples of 5dBm.

For dual Busy Tone Detection on the NT5D31 card, the same
level applies to both tones.

FLVL_MIN

20 - 35

Minimum Frequency Tone level to be detected. Valid entries
are in multiples of 5dBm.

For dual Busy Tone Detection on the NT5D31 card, the same
level applies to both tones.

LD 16 - Configure trunk units and trunk timers in the Route Data Block.

Prompt

Response

Description

REQ

NEW

Add a new data block to the system.

TYPE

RDB

Define a new Route Data Block.

CUST

xx

Customer number, as defined in LD 15

ROUT

Route number

0-511

Range for Large System and CS 1000E system.

0-127

Range for Small System and Media Gateway 1000B.

TKTP

COT

Define trunk type as Central Office.

ICOG

IAO

Incoming and Outgoing trunk.

CNTL

YES

Changes to controls or timers.

Nortel Communication Server 1000

Features and Services - Book 1 of 6 (A to B)

NN43001-106

01.04

Standard

Release 5.0

27 July 2007

Copyright © 2007, Nortel Networks

.

Advertising