Attendant Supervisory Console

4.

"LD 12 – Enable/disable supervisory console for M2250 consoles with
Enhanced Busy Lamp Field and Sile" (page 353)

5.

"LD 15 – Enable/disable an M2250 console using Trunk Group Busy
keys as status keys." (page 353)

LD 15 - Enable/disable feature for an M2250 console with a Console Graphics Module in the
Standard Busy Lamp Field mode.

Prompt

Response

Description

REQ:

CHG

Change existing data.

TYPE:

ATT_DATA

Attendant console options.

CUST

Customer number

0-99

Range for Large System and CS 1000E system.

0-31

Range for Small System and Media Gateway 1000B.

- OPT

(XTG) ITG

Exclude/include Trunk Group Busy Indication.

- SPVC

1-63
0

Attendant number for supervisory console. No supervisory
console.

- - SBLF

(NO) YES

Supervisory lamp field array is not or is to be used to monitor
other attendant consoles.

- ITH1

1-255

Visual indication threshold 1 (number of calls in queue ˇ

S

ITH1 but < ITH2).

- ITH2

2-255

Visual indication threshold 2 (number of calls in queue ˇ

S

ITH2 but < ITH3).

- ITH3

3-255

Visual indication threshold 3 (number of calls in queue ˇ

S

ITH3).

LD 15 - Enable/disable feature for an M2250 console with a Console Graphics Module in the
Enhanced Busy Lamp Field mode.

Prompt

Response

Description

REQ:

CHG

Change existing data.

TYPE:

ATT_DATA

Attendant console options.

CUST

Customer number

0-99

Range for Large System and CS 1000E system.

0-31

Range for Small System and Media Gateway 1000B.

- OPT

(XBL) IBL

Exclude/include Busy Lamp Field or Console Graphics Module.

- - SPVC

1-63
0

Attendant number for supervisory console.
No supervisory console.

- ITH1

1-255

Visual indication threshold 1 (number of calls in queue ˇ

S

ITH1 but < ITH2).

Nortel Communication Server 1000

Features and Services - Book 1 of 6 (A to B)

NN43001-106

01.04

Standard

Release 5.0

27 July 2007

Copyright © 2007, Nortel Networks

.