Nortel Networks NN43001-106 User Manual

Page 564

Advertising
background image

564

Busy Tone Detection for Asia Pacific and CALA

Prompt

Response

Description

NEDC

ETH

Either end control.

FEDC

ETH

Either end control.

LD 14 - Configure Busy Tone Supervision for a new Central Office Trunk.

Prompt

Response

Description

REQ

NEW

Add new data.

TYPE

COT

Central Office trunk.

TN

l s c u

Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.

c u

Format for Small System and Media Gateway 1000B where
c = card and u = unit.

XTRK

EXUT

Type is IPE EXUT. This includes the DXUT. (This prompt is
required only for the first unit defined on each card.)

CUST

xx

Customer number, as defined in LD 15

RTMB

Route number and Member Number

0-511 1-4000

Range for Large System and CS 1000E system.

0-127 1-4000

Range for Small System and Media Gateway 1000B.

SIGL

LOP

Loop start level 3 signaling.

TIMP

(600)
900

Termination Impedance.

BIMP

(3COM)
3CM2
600
900

Balance Impedance. In the case of AUTO_BIMP, this BIMP
value is used as a default value if an optimum AUTO_BIMP is
not found or if the AUTO_BIMP test is not complete.

AUTO_BIM
P

YES

Automatic Balance Impedance is set according to transmission
line parameters.
NO = default for new trunks.

SUPN

YES

Answer and disconnect supervision required.

-STYP

PIP
BTS
PIP BTS

Supervision Type.
Polarity Insensitive Pack.
Busy Tone Supervision.
Both options.

BTDT

(0)-7

Busy Tone Detection Table number configured in LD 97. (This
prompt is required only for the first unit defined on each card.)

CLS

(DIP)
DTN

Dial Pulse.
Digitone.

Nortel Communication Server 1000

Features and Services - Book 1 of 6 (A to B)

NN43001-106

01.04

Standard

Release 5.0

27 July 2007

Copyright © 2007, Nortel Networks

.

Advertising