Autodial Tandem Transfer

Prompt

Response

Description

EEST

YES NO

End-to-end Signaling feedback tone to originating party.

- DTMF

YES NO

Single feedback tone is provided for the user.

With a Yes or No response, single tone feedback is only
available.

LD 16 - Set the duration for Centrex/Trunk Switchhook Flash.

Prompt

Response

Description

REQ

CHG

Change existing data.

TYPE

RDB

Route Data Block.

CUST

xx

Customer number, as defined in LD 15

ROUT

Route number

0-511

Range for Large System and CS 1000E system.

0-127

Range for Small System and Media Gateway 1000B.

TKYP

aaa

Trunk type.

...

CNTL

(NO) YES

Change control or timers.

- TIMR

FLH <space>
60-(510)-1536

Flash timer in msec.
The range of the Centrex switchhook flash timer is
60-(510)-1536. The FLH value is rounded down to the nearest
10 msec. tick. If the value entered is 128 or 129, then it is set
to 130 msec.

Software controlled flash
60-127 msec. Digit 1 will be sent.
128-1536 msec. software controlled switchhook flash.

An FLH timer value of 127 msec. or less is not supported by
the XFCOT card. The firmware controlled flash must be used.

Firmware controlled flash
The user can enter any value from 60 to 1536 msec. 90
msec. is the hardcoded firmware flash for an XFCOT card; the
technician should enter 90 msec.

The FWTM prompt must be set to YES for the trunk associated
with this route in LD 14, if firmware timing is to be used.