LD 15 - Modify data for each customer member to be configured.

Prompt

Response

Description

REQ:

NEW
CHG

Add new data.
Change existing data.

TYPE:

ATT_DATA

Attendant console options.

...

- OPT

(DNCA) DNCS

If DNCA is entered, all DID/CO or DOD calls are disconnected
after the number of ring cycles defined by the response to the
NFNA prompt while the system is in Night Service.

If DNCS is entered, outgoing CO/DOD calls or incoming
CO/DID calls in the answered state, and waiting on a telephone
are disconnected after the number of seconds defined in
response to the NFNS prompt expires.

...

- AFNT

(0)-2-126

Attendant Forward No Answer Timer.

The number of seconds in two-second intervals that the call
is presented to the attendant before Attendant Forward No
Answer is attempted. Odd entries are rounded down to the
next valid entry. If 0 is entered, the call is not forwarded.

- AFBT

(0)-2-x

Attendant Forward Buzz Tone, where:

x = the value defined for AFNT.

The number of seconds in two-second intervals that the
attendant is buzzed at full volume before the Attendant Forward
No Answer timer is reached. Odd entries are rounded down
to the next valid entry.

If 0 is entered, the original volume is in effect.

TYPE:

TIM

Timers.

...