Rockwell Automation Publication 1734-UM013J-EN-P - July 2014

49

Guidelines for Placing Power Supplies and Modules in a System

Chapter 3

To implement a system containing only 1734-IB8S Series B and 1734-OB8S
Series B POINT Guard I/O modules (no POINT Guard I/O Series A modules
used), follow these guidelines.

Series B POINT Guard I/O modules are used without 1734-CTM spacer

modules with ambient operation up to 55

°

C (131

°

F) See

Technical

Specifications for Series B Modules

for Series B POINT Guard I/O

module derating requirements for every module with ambient operation
between 40

°

C (104

°

F) and 55

°

C (131

°

F).

Figure 23 - Placing Series B Digital Modules for up to 55 °C (131 °F) Operation

ATTENTION: Vertical orientation requires careful attention to design details
and panel layout so that all modules in the stack operate within their rated
operating temperature range.

173

4-

AENT

173

4-

OB8S/B

173

4-

IB8S/B

173

4-

OB8S/B

173

4-

IB8S/B

173

4-

OB8S/B

173

4-

IB8S/B

5.08 cm (2 in.)