Figure 43 – Rockwell Automation 1734-IE4S POINT Guard I/O Safety Modules User Manual User Manual

Page 72

Advertising
background image

72

Rockwell Automation Publication 1734-UM013J-EN-P - July 2014

Chapter 4

Install the Module

Figure 43 - Safety Analog Input Wiring for Sinking Tachometer Sensor

Figure 44 - Safety Analog Input Wiring for Sourcing Tachometer Sensor

Follow the

Guidelines for Wiring Safety Analog Inputs on page 65

.

V0

V1

V2

V3

I0

I1

I2

I3

COM

COM

COM

COM

COM

COM

COM

COM

S0

S1

S2

S3

S0

S1

S2

S3

Sinking Sensor

(NPN-type)

1734-TOP3 Terminal Bases

Metal Oxide or
Carbon
Composition

1k
2W

25

20

15

10

5

0

Edge-to-edge Time

Measured Here

1734-IE4S with Trigger = Falling Edge

Transistor Pull-down

Resistor Pull-up

Ele

ct

ron

ic

s

V0

V1

V2

V3

I0

I1

I2

I3

COM

COM

COM

COM

COM

COM

COM

COM

S0

S1

S2

S3

S0

S1

S2

S3

1734-TOP3 Terminal Bases

Sourcing Sensor

(PNP-type)

Metal Oxide or
Carbon
Composition

1k
2W

25

20

15

10

5

0

Edge-to-edge Time

Measured Here

1734-IE4S with Trigger = Rising Edge

Resistor Pull-
down

Transistor
Pull-up

El

ec

tr

oni

cs

Advertising