Cub Cadet I-Beam Style User Manual

Page 256

Advertising
background image

6-57

6

2. Start the engine and move the throttle (if

equipped) to fast._____

NOTE

Most log splitters do not have a throttle control,
they are set to run at full throttle at all times.

3. Check the engine RPM with a tachometer and

make certain the engine is running between
3500 and 3600 RPM._____ See Figure 6-74.

NOTE

If the engine is not running to specifications,
the test results will not be valid. See the engine
service manual to correct the engine RPM.

4. The log splitter must be run for a short time to

bring the hydraulic fluid up to 130 degrees
Fahrenheit before continuing this test._____

5. Record the GPM of the fluid flow at the flow

meter._____ See Figure 6-75.

NOTE

The flow meter should read between 8 and 14
GPM (gallons-per-minute) if the pump is oper-
ating correctly.

6. Record the pressure of the fluid at the pressure

gauge._____

NOTE

The pressure gauge should read 0 PSI
(pounds-per-square-inch) if the pump is oper-
ating correctly.

7. Slowly close the needle valve clockwise until

the engine begins to labor._____

8. Continue to close the needle valve slowly until

the high volume check valve closes and the
engine RPM returns to normal._____ See Fig-
ure 6-76.

Figure 6-73.

Figure 6-74.

Figure 6-75.

Log Splitters 2.fm Page 57 Wednesday, February 20, 2002 1:35 PM

Advertising