9.

Record the PSI._____

NOTE

The PSI reading should be between 300 and
700 PSI.

10. Record the GPM._____

NOTE

The GPM reading should be between 1 and 3
GPM.

IMPORTANT: If the check valve does not
close, the engine will bog down and stall.
(REPLACE THE PUMP).

11. If all the recorded data meets the specifica-

tions above, proceed._____

CAUTION

The next test requires the needle valve to be
almost fully closed. It must be opened immedi-
ately after recording the test results to avoid
damage._____

Final Pump Pressure Test

1. Continue to close the needle valve slowly until

the flow gauge reads approximately 1
GPM._____ See Figure 6-77.

NOTE

DO NOT close the needle valve fully. This is
the main pressure hose, and the pump does
not have a relief valve.

2. Record the PSI._____ This is PSI “A”

NOTE

The PSI “A” should be between 1500 and 3200
PSI.

3.

Record the GPM._____ This is GPM “A”

NOTE

The GPM “A” should be approximately 1 GPM.

4.

Immediately open the needle valve._____

NOTE

Damage to the pump can be avoided by open-
ing the needle valve immediately after record-
ing the test results.

5. If the PSI reading is below 1500 PSI and the

GPM is above 1 to 2, the pump is defective.
(REPLACE THE PUMP).

6. Shut the log splitter off.

7. If all the recorded data meets the specifica-

tions above, perform the following section.

Figure 6-76.

Figure 6-77.

Log Splitters 2.fm Page 58 Wednesday, February 20, 2002 1:35 PM

Advertising