6-60

12. If the (PSI “B”) is less than the recorded (PSI

“A”) in the Final Pump Pressure Test, there
may be a problem with the control valve, pres-
sure relief valve or hydraulic cylinder. Continue
through this section to determine which part is
faulty.

13. Move the control valve to reverse and retract

the wedge assembly.

14. Shut the log splitter off and relieve the pres-

sure in the hydraulic system by cycling the
control valve handle forward to reverse several
times.

15. Remove the test kit from the log splitter using a

7/8" wrench, 1-1/8", 1-1/16" and a large adjust-
able wrench.

16. Install the high pressure hydraulic hose in the

inlet port of the control valve using a 1-1/16"
wrench and channel locks. See Figure 6-82.

Control Valve, Pressure Relief
Valve and Hydraulic Cylinder Testing

1.

Make certain the wedge assembly is in the fully
retracted position._____ See Figure 6-83.

2. Place the log splitter in the vertical position and

lock it in._____

3. Remove the steel hydraulic tube that connects

from the rear port of the hydraulic cylinder to
the 90 degree fitting on the control valve using
two 7/8" wrenches._____ See Figure 6-84.

Install the Test Kit in the
Following Sequence

Figure 6-81.

Figure 6-82.

Figure 6-83.

Figure 6-84.