Aem-2020 (analog expansion module), Cem-2020 (contact expansion module), Lsm-2020 (load share module) – Winco DGC-2020 User Manual

Page 15: Style and part numbers, Style number, Aem-2020 (analog expansion module) -3, Cem-2020 (contact expansion module) -3, Lsm-2020 (load share module) -3, Style and part numbers -3, Style number -3

Advertising
background image

AEM-2020 (ANALOG EXPANSION MODULE)

The optional AEM-2020 provides eight remote analog inputs, eight remote RTD inputs, two remote
thermocouple inputs, and four remote analog outputs to the DGC-2020. The AEM-2020 communicates
with the DGC-2020 through a CANbus interface. Refer to Section 10, AEM-2020 (Analog Expansion
Module),

for more information.

CEM-2020 (CONTACT EXPANSION MODULE)

The optional CEM-2020 provides 10 additional contact inputs and 24 additional output contacts to the
DGC-2020. The CEM-2020 communicates with the DGC-2020 through a CANbus interface. Refer to
Section 9, CEM-2020 (Contact Expansion Module), for more information.

LSM-2020 (LOAD SHARE MODULE)

The optional LSM-2020 in conjunction with the DGC-2020 provides load sharing between governors
through an analog load share line. The LSM-2020 communicates through an Ethernet port and provides
access to the DGC-2020 via Ethernet. Refer to Section 8, LSM-2020 (Load Share Module), for more
information.

STYLE AND PART NUMBERS

Style Number
Standard-order DGC-2020 controllers are identified by a style number which consists of a combination of
letters and numbers that define the controller’s electrical characteristics and operational features. The
model number, together with the style number, describes the options included in a specific controller.
Figure 1-1 illustrates the DGC-2020 style number identification chart.

Figure 1-1. DGC-2020 Style Chart

For example, if a DGC-2020 style number were 51BNBMEAH, the controller would have the following
characteristics and operating features.
5

5 Aac current sensing inputs

1

50/60 hertz nominal generator frequency

B

Three fixed-function output contacts and 12 programmable output contacts

N

No RS-485 communication port

B

Battery backup for real-time clock during losses of control power

M

Internal dial-out modem—US version

E

Enhanced generator protection (undervoltage, reverse power, loss of excitation, phase imbalance,

overcurrent, overvoltage, overfrequency, and underfrequency)

A

Auto-synchronizer

H

LCD heater

9400200990 Rev K

DGC-2020 General Information