General information, Features, Specifications – Winco DGC-2020 User Manual

Page 237: Operating power, Contact inputs, Output contacts, Communication interface, Canbus, Type tests, Shock

Advertising
background image

9400200990 Rev K

DGC-2020 CEM-2020 (Contact Expansion Module)

9-1

SECTION 9

CEM-2020 (CONTACT EXPANSION

MODULE)

GENERAL INFORMATION

The optional CEM-2020 is a remote auxiliary device that provides additional DGC-2020 contact inputs
and outputs.

FEATURES

CEM-2020s have the following features:

 10 Contact Inputs

 24 Output Contacts

 Functionality of Inputs and Outputs assigned by BESTLogic+ programmable logic

 Communications via CANbus

SPECIFICATIONS

Operating Power

Nominal:

12 or 24 Vdc

Range:

8 to 32 Vdc (Withstands cranking ride-through down to 6 Vdc
for 500 ms.)

Maximum Consumption:

14 W

Contact Inputs

The CEM-2020 contains 10 programmable inputs that accept normally open and normally closed, dry
contacts.

Time from a CEM-2020 input going high to:

Shutdown the generator via an alarm:

700 ms max

Close a relay on board the DGC-2020:

300 ms max

Output Contacts

Ratings

Outputs 13 through 24:

1 Adc at 30 Vdc, Form C, gold contacts

Outputs 25 through 36:

4 Adc at 30 Vdc, Form C

Communication Interface

CANbus

Differential Bus Voltage:

1.5 to 3 Vdc

Maximum Voltage:

–32 to +32 Vdc with respect to negative battery terminal

Communication Rate:

250 kb/s

Type Tests

Shock

15 G in 3 perpendicular planes

Vibration

Swept over the following ranges for 12 sweeps in each of three mutually perpendicular planes with each
15-minute sweep consisting of the following:

5 to 29 to 5 Hz:

1.5 G peak for 5 min.

29 to 52 to 29 Hz:

0.036” Double Amplitude for 2.5 min.

52 to 500 to 52 Hz:

5 G peak for 7.5 min.

Ignition System

Tested in closed proximity to an unshielded, unsuppressed Altronic DISN 800 ignition system.

Advertising