Communication interface, Canbus, Ethernet – Winco DGC-2020 User Manual

Page 222: Type tests, Shock, Vibration, Ignition system, Halt (highly accelerated life testing), Environment, Ul approval

Advertising
background image

8-2

DGC-2020 LSM-2020 (Load Share Module)

9400200990 Rev K

Communication Interface

CANbus

Differential Bus Voltage:

1.5 to 3 Vdc

Maximum Voltage:

–32 to +32 Vdc with respect to negative battery terminal

Communication Rate:

250 kb/s

Terminals:

P2-12 (low), P2-11 (high), and P2-10 (shield)

Ethernet

Rear-panel RJ-45 connector provides remote communications via BESTCOMSPlus to the LSM-2020 and
to the DGC-2020 that the module is connected to.

Type:

10/100BASE-T

Industrial Ethernet devices designed to comply with IEC 61000-4 series of specifications are
recommended.

Type Tests

Shock

15 G in 3 perpendicular planes

Vibration

Swept over the following ranges for 12 sweeps in each of three mutually perpendicular planes with each
15-minute sweep consisting of the following:

5 to 29 to 5 Hz:

1.5 G peak for 5 min.

29 to 52 to 29 Hz:

0.036” Double Amplitude for 2.5 min.

52 to 500 to 52 Hz:

5 G peak for 7.5 min.

Ignition System

Tested in closed proximity to an unshielded, unsuppressed Altronic DISN 800 ignition system.

HALT (Highly Accelerated Life Testing)

HALT is used by Basler Electric to prove that our products will provide the user with many years of
reliable service. HALT subjects the device to extremes in temperature, shock, and vibration to simulate
years of operation, but in a much shorter period span. HALT allows Basler Electric to evaluate all possible
design elements that will add to the life of this device. As an example of some of the extreme testing
conditions, the LSM-2020 was subjected to temperature tests (tested over a temperature range of –80

C

to +130

C),

vibration tests (of 5 to 50 G at +25

C), and temperature/vibration tests (tested at 10 to 20 G

over a temperature range of –60

C to +100C). Combined temperature and vibration testing at these

extremes proves that the LSM-2020 is expected to provide long-term operation in a rugged environment.
Note that the vibration and temperature extremes listed in this paragraph are specific to HALT and do not
reflect recommended operation levels. These operational ratings are included in Section 8 of this manual.

Environment

Temperature
Operating:

–40

to

+70

C (–40 to +158F)

Storage: –40

to

+85

C (–40 to +185F)

Humidity:

IEC

68-2-38

UL Approval

“cURus” recognized to UL Standard 508 & CSA Standard C22.2 No.14

“cURus” recognized per Standard 1604, Electrical Equipment for Use in Class I and II, Division 2, and
Class III Hazardous (Classified) Locations,
Class I, Division 2, Zone 2, Groups A, B, C, D,
Temperature Code - T4.

NFPA Compliance

Complies with NFPA Standard 110, Standard for Emergency and Standby Power.

Advertising