Hard IP Reconfiguration

14

2014.12.15

Subscribe

Send Feedback

The Arria V Hard IP for PCI Express reconfiguration block allows you to dynamically change the value of

configuration registers that are read-only. You access this block using its Avalon-MM slave interface. You

must enable this optional functionality by turning on Enable Hard IP Reconfiguration in the parameter

editor. For a complete description of the signals in this interface, refer to Hard IP Reconfiguration

Interface.
The Hard IP reconfiguration block provides access to read-only configuration registers, including

Configuration Space, Link Configuration, MSI and MSI-X capabilities, Power Management, and

Advanced Error Reporting (AER). This interface does not support simulation.
The procedure to dynamically reprogram these registers includes the following three steps:
1. Bring down the PCI Express link by asserting the

hip_reconfig_rst_n

reset signal, if the link is

already up. (Reconfiguration can occur before the link has been established.)

2. Reprogram configuration registers using the Avalon-MM slave Hard IP reconfiguration interface.

3. Release the

npor

reset signal.

Note: You can use the LMI interface to change the values of configuration registers that are read/write at

run time. For more information about the LMI interface, refer to LMI Signals.

Contact your Altera representative for descriptions of the read-only, reconfigurable registers.

Related Information

LMI Signals

on page 4-42

©

2014 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134

Advertising
This manual is related to the following products: