Power Management Signals

Table 4-17: Power Management Signals

Signal

Direction

Description

pme_to_cr

Input

Power management turn off control register.
Root Port—When this signal is asserted, the Root Port sends the

PME_turn_off

message.

Endpoint—This signal is asserted to acknowledge the

PME_turn_

off

message by sending

pme_to_ack

to the Root Port.

pme_to_sr

Output

Power management turn off status register.
Root Port—This signal is asserted for 1 clock cycle when the Root

Port receives the

pme_turn_off

acknowledge message.

Endpoint—This signal is asserted for 1 cycle when the Endpoint

receives the

PME_turn_off

message from the Root Port.

pm_event

Input

Power Management Event. This signal is only available for

Endpoints.
The Endpoint initiates a a

power_management_event

message

(PM_PME) that is sent to the Root Port. If the Hard IP is in a low

power state, the link exits from the low-power state to send the

message. This signal is positive edge-sensitive.

pm_event_func[2:0]

Input

Specifies the function associated with a Power Management

Event.

2014.12.15