Saving power – Microsens MS453490M Management Guide User Manual

Page 148

Advertising
background image

C

HAPTER

5

| Interface Configuration

Saving Power

– 148 –

S

AVING

P

OWER

Use the Interface > Green Ethernet page to enable power savings mode on

the selected port.

CLI R

EFERENCES

"power-save" on page 714

"show power-save" on page 715

C

OMMAND

U

SAGE

IEEE 802.3 defines the Ethernet standard and subsequent power

requirements based on cable connections operating at 100 meters.
Enabling power saving mode can reduce power used for cable lengths

of 60 meters or less, with more significant reduction for cables of 20

meters or less, and continue to ensure signal integrity.

The power-saving methods provided by this switch include:

Power saving when there is no link partner:
Under normal operation, the switch continuously auto-negotiates to

find a link partner, keeping the MAC interface powered up even if no

link connection exists. When using power-savings mode, the switch

checks for energy on the circuit to determine if there is a link

partner. If none is detected, the switch automatically turns off the

transmitter, and most of the receive circuitry (entering Sleep Mode).

In this mode, the low-power energy-detection circuit continuously

checks for energy on the cable. If none is detected, the MAC

interface is also powered down to save additional energy. If energy

is detected, the switch immediately turns on both the transmitter

and receiver functions, and powers up the MAC interface.

Power saving when there is a link partner:
Traditional Ethernet connections typically operate with enough

power to support at least 100 meters of cable even though average

network cable length is shorter. When cable length is shorter, power

consumption can be reduced since signal attenuation is proportional

to cable length. When power-savings mode is enabled, the switch

analyzes cable length to determine whether or not it can reduce the

signal amplitude used on a particular link.

N

OTE

:

Power savings can only be implemented on Gigabit Ethernet ports

when using twisted-pair cabling. Power-savings mode on a active link only

works when connection speed is 1 Gbps, and line length is less than 60

meters.