Port mirroring commands, Local port mirroring commands, 29 p – Microsens MS453490M Management Guide User Manual

Page 727: Irroring, Ommands, Port monitor, Table 93: port mirroring commands, Table 94: mirror port commands

Advertising
background image

– 727 –

29

P

ORT

M

IRRORING

C

OMMANDS

Data can be mirrored from a local port on the same switch or from a

remote port on another switch for analysis at the target port using

software monitoring tools or a hardware probe. This switch supports the

following mirroring modes.

L

OCAL

P

ORT

M

IRRORING

C

OMMANDS

This section describes how to mirror traffic from a source port to a target

port.

port monitor

This command configures a mirror session. Use the no form to clear a

mirror session.

S

YNTAX

port monitor {interface [rx | tx | both] | vlan vlan-id |

mac-address mac-address}

no port monitor interface

interface - ethernet unit/port (source port)

unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-10)

rx - Mirror received packets.
tx - Mirror transmitted packets.
both - Mirror both received and transmitted packets.
vlan-id - VLAN ID (Range: 1-4093)

Table 93: Port Mirroring Commands

Command

Function

Local Port Mirroring

Mirrors data to another port for analysis without affecting the data

passing through or the performance of the monitored port

RSPAN Mirroring

Mirrors data from remote switches over a dedicated VLAN

Table 94: Mirror Port Commands

Command

Function

Mode

port monitor

Configures a mirror session

IC

show port monitor

Shows the configuration for a mirror port

PE