Test cable-diagnostics, Test cable- diagnostics – Microsens MS453490M Management Guide User Manual

Page 713

Advertising
background image

C

HAPTER

27

| Interface Commands

– 713 –

test cable-

diagnostics

This command performs cable diagnostics on the specified port to diagnose

any cable faults (short, open, etc.) and report the cable length.

S

YNTAX

test cable-diagnostics interface interface

interface

ethernet unit/port

unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-10)

C

OMMAND

M

ODE

Privileged Exec

C

OMMAND

U

SAGE

Cable diagnostics are performed using Digital Signal Processing (DSP)

test methods.

This cable test is only accurate for cables 7 - 140 meters long.

The test takes approximately 5 seconds. The switch displays the results

of the test immediately upon completion, including common cable

failures, as well as the status and approximate length of each cable

pair.

Potential conditions which may be listed by the diagnostics include:

OK: Correctly terminated pair

Open: Open pair, no link partner

Short: Shorted pair

Not Supported: This message is displayed for any Fast Ethernet

ports that are linked up, or for any Gigabit Ethernet ports linked up

at a speed lower than 1000 Mbps.

Impedance mismatch: Terminating impedance is not in the

reference range.

Ports are linked down while running cable diagnostics.

E

XAMPLE

Console#test cable-diagnostics interface ethernet 1/10

Console#show cable-diagnostics interface e 1/10

Port Type Link Status Pair A (meters) Pair B (meters) Last Update

-------- ---- ----------- ---------------- ---------------- -----------------

Eth 1/10 GE Up OK (21) OK (21) 2009-11-13 09:44:19

Console#