Show power-save – Microsens MS453490M Management Guide User Manual

Page 715

Advertising
background image

C

HAPTER

27

| Interface Commands

– 715 –

partner. If none is detected, the switch automatically turns off the

transmitter, and most of the receive circuitry (entering Sleep Mode).

In this mode, the low-power energy-detection circuit continuously

checks for energy on the cable. If none is detected, the MAC

interface is also powered down to save additional energy. If energy

is detected, the switch immediately turns on both the transmitter

and receiver functions, and powers up the MAC interface.

Power saving when there is a link partner:
Traditional Ethernet connections typically operate with enough

power to support at least 100 meters of cable even though average

network cable length is shorter. When cable length is shorter, power

consumption can be reduced since signal attenuation is proportional
to cable length. When power-savings mode is enabled, the switch

analyzes cable length to determine whether or not it can reduce the

signal amplitude used on a particular link.

N

OTE

:

Power-savings mode on a active link only works when the

connection speed is 100 Mbps or higher at linkup, and line length is less

than 60 meters.

N

OTE

:

Power savings can only be implemented on Gigabit Ethernet ports

using twisted-pair cabling. Power-savings mode on a active link only works

when connection speed is 1 Gbps, and line length is less than 60 meters.

E

XAMPLE

Console(config)#interface ethernet 1/10

Console(config-if)#power-save

Console(config-if)#

show power-save

This command shows the configuration settings for power savings.

S

YNTAX

show power-save [interface interface]

interface

ethernet unit/port

unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-10)

C

OMMAND

M

ODE

Privileged Exec