If a login attempt is not detected within the timeout interval, the

connection is terminated for the session.

This command applies to both the local console and Telnet connections.

The timeout for Telnet cannot be disabled.

Using the command without specifying a timeout restores the default

setting.

E

XAMPLE

To set the timeout to two minutes, enter this command:

Console(config-line)#timeout login response 120

Console(config-line)#

disconnect

This command terminates an SSH, Telnet, or console connection.

S

YNTAX

disconnect session-id

session-id – The session identifier for an SSH, Telnet or console

connection. (Range: 0-4)

C

OMMAND

M

ODE

Privileged Exec

C

OMMAND

U

SAGE

Specifying session identifier “0” will disconnect the console connection.

Specifying any other identifiers for an active session will disconnect an SSH

or Telnet connection.

E

XAMPLE

Console#disconnect 1

Console#

R

ELATED

C

OMMANDS

show ssh (618)

show users (507)