rmon alarm

This command sets threshold bounds for a monitored variable. Use the no

form to remove an alarm.

S

YNTAX

rmon alarm index variable interval seconds {absolute | delta}

rising-threshold threshold event event-index falling-threshold

threshold event event-index [owner name]
no rmon event index
index
– Index to this entry. (Range: 1-65535)
variable – The object identifier of the MIB variable to be sampled.

Only variables of the type etherStatsEntry.n.n may be sampled.

Note that etherStatsEntry.n uniquely defines the MIB variable, and

etherStatsEntry.n.n defines the MIB variable, plus the

etherStatsIndex. For example, 1.3.6.1.2.1.16.1.1.1.6.1 denotes

etherStatsBroadcastPkts, plus the etherStatsIndex of 1.
seconds – The polling interval. (Range: 1-31622400 seconds)
absolute – The variable is compared directly to the thresholds at

the end of the sampling period.
delta – The last sample is subtracted from the current value and

the difference is then compared to the thresholds.
threshold – An alarm threshold for the sampled variable.

(Range: 1-65535)
event-index – The index of the event to use if an alarm is triggered.

If there is no corresponding entry in the event control table, then no

event will be generated. (Range: 1-65535)
name – Name of the person who created this entry. (Range: 1-127

characters)

D

EFAULT

S

ETTING

None

C

OMMAND

M

ODE

Global Configuration

C

OMMAND

U

SAGE

If an event is already defined for an index, the entry must be deleted

before any changes can be made with this command.

If the current value is greater than or equal to the rising threshold, and

the last sample value was less than this threshold, then an alarm will be

generated. After a rising event has been generated, another such event

will not be generated until the sampled value has fallen below the rising

threshold, reaches the falling threshold, and again moves back up to

the rising threshold.

If the current value is less than or equal to the falling threshold, and

the last sample value was greater than this threshold, then an alarm

will be generated. After a falling event has been generated, another