[SwitchD] multicast routing-enable

[SwitchD] interface vlan-interface 300

[SwitchD-Vlan-interface300] igmp enable

[SwitchD-Vlan-interface300] pim sm

[SwitchD-Vlan-interface300] quit

[SwitchD] interface vlan-interface 400

[SwitchD-Vlan-interface400] pim sm

[SwitchD-Vlan-interface400] quit

[SwitchD] interface vlan-interface 103

[SwitchD-Vlan-interface103] pim sm

[SwitchD-Vlan-interface103] quit

[SwitchD] pim

[SwitchD-pim] bidir-pim enable

[SwitchD-pim] quit

4.

On Switch C, configure VLAN interface 102 as a C-BSR, and loopback interface 0 as a C-RP for

the entire BIDIR-PIM domain.

[SwitchC-pim] c-bsr vlan-interface 102

[SwitchC-pim] c-rp loopback 0 bidir

[SwitchC-pim] quit

Verifying the configuration

# Display the DF information of BIDIR-PIM on Switch A.

[SwitchA] display pim df-info

VPN-Instance: public net

RP Address: 1.1.1.1

Interface State DF-Pref DF-Metric DF-Uptime DF-Address

Vlan100 Win 100 2 01:08:50 192.168.1.1 (local)

Vlan101 Lose 100 1 01:07:49 10.110.1.2

# Display the DF information of BIDIR-PIM on Switch B.

[SwitchB] display pim df-info

VPN-Instance: public net

RP Address: 1.1.1.1

Interface State DF-Pref DF-Metric DF-Uptime DF-Address

Vlan200 Win 100 1 01:24:09 192.168.2.1 (local)

Vlan101 Win 100 1 01:24:09 10.110.1.2 (local)

Vlan102 Lose 0 0 01:23:12 10.110.2.2

# Display the DF information of BIDIR-PIM on Switch C.

[SwitchC] display pim df-info

VPN-Instance: public net

RP Address: 1.1.1.1

Interface State DF-Pref DF-Metric DF-Uptime DF-Address

Loop0 - - - - -

Vlan102 Win 0 0 01:06:07 10.110.2.2 (local)

Vlan103 Win 0 0 01:06:07 10.110.3.1 (local)

# Display the DF information of BIDIR-PIM on Switch D.

Advertising