39

Figure 16 Network diagram

Configuration procedure

1.

Configure Device A:
# Enable IGMP snooping globally.

<DeviceA> system-view

[DeviceA] igmp-snooping

[DeviceA-igmp-snooping] quit

# Create VLAN 100 and assign GigabitEthernet 3/0/1 through GigabitEthernet 3/0/3 to the

VLAN.

[DeviceA] vlan 100

[DeviceA-vlan100] port GigabitEthernet 3/0/1 to GigabitEthernet 3/0/3

# Enable IGMP snooping and the function of dropping unknown multicast traffic in VLAN 100.

[DeviceA-vlan100] igmp-snooping enable

[DeviceA-vlan100] igmp-snooping drop-unknown

# Enable the IGMP snooping querier function in VLAN 100

[DeviceA-vlan100] igmp-snooping querier

# Set the source IP address of IGMP general queries and group-specific queries to 192.168.1.1
in VLAN 100.

[DeviceA-vlan100] igmp-snooping general-query source-ip 192.168.1.1

[DeviceA-vlan100] igmp-snooping special-query source-ip 192.168.1.1

[DeviceA-vlan100] quit

2.

Configure Device B:
# Enable IGMP snooping globally.

<DeviceB> system-view

[DeviceB] igmp-snooping

[DeviceB-igmp-snooping] quit

# Create VLAN 100, and assign GigabitEthernet 3/0/1 through GigabitEthernet 3/0/4 to the
VLAN.

[DeviceB] vlan 100

Advertising