Verifying the configuration – H3C Technologies H3C S12500 Series Switches User Manual

Page 432

Advertising
background image

416

[SwitchB] interface vlan-interface 102

[SwitchB-Vlan-interface102] multicast ipv6 boundary scope 4

[SwitchB-Vlan-interface102] quit

[SwitchB] interface vlan-interface 103

[SwitchB-Vlan-interface103] multicast ipv6 boundary scope 4

[SwitchB-Vlan-interface103] quit

# On Switch C, configure VLAN-interface 103 and VLAN-interface 106 to be the boundary of
admin-scoped zone 2.

<SwitchC> system-view

[SwitchC] interface vlan-interface 103

[SwitchC-Vlan-interface103] multicast ipv6 boundary scope 4

[SwitchC-Vlan-interface103] quit

[SwitchC] interface vlan-interface 106

[SwitchC-Vlan-interface106] multicast ipv6 boundary scope 4

[SwitchC-Vlan-interface106] quit

# On Switch D, configure VLAN-interface 107 to be the boundary of admin-scoped zone 2.

<SwitchD> system-view

[SwitchD] interface vlan-interface 107

[SwitchD-Vlan-interface107] multicast ipv6 boundary scope 4

[SwitchD-Vlan-interface107] quit

5.

Configure C-BSRs and C-RPs:
# On Switch B, configure the service scope of RP advertisements and configure VLAN-interface
101 as a C-BSR and C-RP of admin-scoped zone 1.

[SwitchB] pim ipv6

[SwitchB-pim6] c-bsr scope 4

[SwitchB-pim6] c-bsr 1002::2

[SwitchB-pim6] c-rp 1002::2 scope 4

[SwitchB-pim6] quit

# On Switch D, configure the service scope of RP advertisements and configure VLAN-interface

104 as a C-BSR and C-RP of admin-scoped zone 2.

[SwitchD] pim ipv6

[SwitchD-pim6] c-bsr scope 4

[SwitchD-pim6] c-bsr 3002::2

[SwitchD-pim6] c-rp 3002::2 scope 4

[SwitchD-pim6] quit

# On Switch F, configure VLAN-interface 109 as a C-BSR and C-RP in the global-scoped zone.

<SwitchF> system-view

[SwitchF] pim ipv6

[SwitchF-pim6] c-bsr scope global

[SwitchF-pim6] c-bsr 8001::1

[SwitchF-pim6] c-rp 8001::1

[SwitchF-pim6] quit

Verifying the configuration

To view the BSR election information and the C-RP information on a switch, use the display pim

ipv6 bsr-info command. For example:
# Display the BSR information and the locally configured C-RP information on Switch B.

Advertising