(4) Positioning band was entered with a wrong sign

Take note that if a value with a wrong sign is set in the “Positioning band” field of the position table, the operation
will deviate by a distance corresponding to “positioning band x 2,” as shown below.











2.2.3 Speed

Change

during Movement

Speed control involving multiple speed levels is possible in a single operation. The actuator speed can be
decreased or increased at a certain point during movement.
However, the position at which to implement each speed change must be set.







2.2.4

Operation at Different Acceleration and Deceleration Settings

If the load is a CCD camera or other precision equipment, the deceleration curb at stop must be made as
gradual as possible.
To accommodate these sensitive applications, the position table has separate fields for “acceleration” and
“deceleration.”
For example, you can set the deceleration differently from the acceleration, such as setting 0.3 G (rated
acceleration) in “Acceleration” and 0.1 G in “Deceleration.”










Caution: Basically, the acceleration and deceleration should be inside the rated acceleration/deceleration

range specified in the catalog.
The input range is greater than the rated range in the catalog, but this is only to accommodate
situations where you want to “reduce the tact time when the load mass is significantly smaller than
the rated load capacity.”
If you want to use acceleration/deceleration settings greater than the rating, consult IAI beforehand
because it may affect the life of the actuator.

Speed

Moving
distance

Positioning

band

Positioning

band

Positioning

band

Actual position reached

(the load was missed)

Target position

Position 1 Position 2 Position 1

Position 2

Position 1 Position 2 Position 3

Speed

Acceleration:
0.3 G

Deceleration:
0.1 G

Starting
position

Target

position

Time