176

Appendix


The table below lists the absolute-encoder backup specifications.

List of absolute-encoder backup functions
Battery model

AB-5 (by IAI)

Battery voltage

3.6 V

Current capacity

2000 mAH

Detection voltage for battery
voltage low alarm

(Typical)

3.1 V, 3.0 V to 3.2 V

Detection voltage for battery
voltage low error

(Typical)

2.5 V, 2.3 V to 2.7 V

Time after alarm detection until
error detection (reference)

10 days if the controller is operated continuously at 20

C, or 7 days if no

power is supplied
10 days if the controller is operated continuously at 40

C, or 2.5 days if no

power is supplied

Minimum data retention voltage

2.7 V min. (Varies depending on the encoder characteristics.)

Time after alarm detection until
data loss (reference)

With an absolute encoder, absolute reset must always be performed once an
error has been detected.

Data assurance limit during
battery replacement

15 minutes (Maximum time during
which data can be retained without
any battery in the battery holder)

Data is retained by the super
capacitor in the absolute brake unit.

Temperature 40

C, power supplied

0% of the time

2 years

Reference battery replacement
interval

Temperature 40

C, power supplied

50% of the time

4 years