3 pulse-train control service cable – IAI America SCON-C User Manual

Page 164

Advertising
background image




146

1.3.3

Pulse-train Control Service Cable

Model: CB-SC-PIOS



* Enter the cable length in

. Lengths up to 10 m can be specified. Example) 020 = 2 m

(The maximum cable length is 2 m if the AK-04 is used to convert open-collector pulses.)

Description: Plug + Shell + Shielded cable
Use this cable to connect pulse-train control signals to the host equipment.
The cable does not have a connector on the host equipment end.
The customer should connect the cable to the host equipment by processing the host equipment end of the
cable in accordance with the equipment to be connected.



































Wire Color

Symbol

Signal name

No.

Connect the shield to the hood using a clamp.

Black

White/Black

Red

White/Red

Green

White/Green

Yellow

White/Yellow

Brown

White/Brown

Blue

White/Blue

Gray

White/Gray

0.2 sq.,

soldered

Pulse-train input

Line-driver output line for
feedback pulse output

Host equipment
end

Shield

Plug: 10114-3000PE

(Sumitomo 3M)

Shell: 10314-52F0-008 (Sumitomo 3M)

Pin 1

Pin 8

CB-SC-PIOS***




PP

/PP

NP

/NP

AFB

/AFB

BFB

/BFB

ZFB

/ZFB

GND

GND

+A

-A

+B

-B

+Z

-Z

1
2

3

4

5
6

7
8

9

10
11

12

13

14