 PIO pattern = 4 Solenoid valve mode 1 [7-point type]

Category Signal

name

Signal

abbreviation

Function overview

Position No. 0 move

ST0

The actuator starts moving to position No. 0 when this signal turns
ON.

Position No. 1 move

ST1

The actuator starts moving to position No. 1 when this signal turns
ON.

Position No. 2 move

ST2

The actuator starts moving to position No. 2 when this signal turns
ON.

Position No. 3 move

ST3

The actuator starts moving to position No. 3 when this signal turns
ON.

Position No. 4 move

ST4

The actuator starts moving to position No. 4 when this signal turns
ON.

Position No. 5 move

ST5

The actuator starts moving to position No. 5 when this signal turns
ON.

Position No. 6 move

ST6

The actuator starts moving to position No. 6 when this signal turns
ON.

Brake release

BKRL

This signal is used on an actuator equipped with a brake to forcibly
release the brake.

Operating mode

RMOD

This signal switches the operating mode between AUTO and MANU.
(ON: MANU, OFF: AUTO)

Home return

HOME

Home return operation is started at a rise edge of this signal.

Pause *STP

ON: Actuator can be moved, OFF: Actuator decelerates to a stop

Alarm reset

RES

An alarm is reset at a rise edge of this signal.

Input

Servo ON

SON

The servo remains ON while this signal is ON.
The servo remains OFF while this signal is OFF.

Position No. 0 complete PE0

This signal will turn ON when the actuator completes moving to
position No. 0.

Position No. 1 complete PE1

This signal will turn ON when the actuator completes moving to
position No. 1.

Position No. 2 complete PE2

This signal will turn ON when the actuator completes moving to
position No. 2.

Position No. 3 complete PE3

This signal will turn ON when the actuator completes moving to
position No. 3.

Position No. 4 complete PE4

This signal will turn ON when the actuator completes moving to
position No. 4.

Position No. 5 complete PE5

This signal will turn ON when the actuator completes moving to
position No. 5.

Position No. 6 complete PE6

This signal will turn ON when the actuator completes moving to
position No. 6.

Zone 1

ZONE1

This signal becomes effective after home return. It will turn ON when
the current actuator position enters the range set by the parameters
and remain ON until the actuator exits the range.

Position zone

PZONE

This signal becomes effective when the current actuator position is
in the range specified in the position table, while a position
movement command is input.

Operating mode status

RMDS

A signal indicating the operating mode of AUTO or MANU is output.

Home return completion

HEND

This signal is OFF immediately after the power is input, and turns
ON when home return has completed.

Position complete

PEND

This signal turns ON when the actuator has moved to the target
position and entered the positioning band. It is used to determine if
the positioning has completed.

Servo-on status

SV

This signal is always output once the servo is turned ON and the
controller is ready to operate.

Emergency stop status

*EMGS

OFF: Emergency stop has been actuated

Alarm *ALM

This signal remains ON in normal conditions of use and turns OFF
when an alarm generates.

Output

Battery alarm

*BALM

This signal is ON when the absolute battery voltage is normal or an
incremental encoder is used.