Precautions

Please use rotary actuators of multi-rotation specification within the range where the following formula is
satisfied. Moreover, the maximum rotation angle is

±9999 [deg]

(NOTE1)

(maximum software stroke limit).


• Maximum rotation angle: Set the usage conditions (maximum -9999 to 9999 [deg]).

Note 1 :The following models can not be rotated up to ±9999.99 [deg].

deceleration
ratio

Maximum rotation angle
[deg]

corresponding model

1/24

±

7679.99 RCS2-RTC8、RCS2-RTC10

1/30

±

6143.99

RCS2-RTC12

1/50

±

3685

1/100

±

1842

RS-30、RS-60

• Unit movement: The amount of movement per command pulse.



Example) In case RCS2-RTC8L-I-12-24(deceleration ratio:1/24) is operated maximum rotation

angle 6000 [deg].






Therefore, the actuator can be operated in this case.






±2

23

Maximum rotation angle [deg]

Unit Travel Distance [deg/pulse]

±2

23

Maximum rotation angle [deg]

Unit Travel Distance [deg/pulse]

×

360[deg/rev]

× Rotary Axis deceleration Ratio

No. of Encoder Pluses [pulse/rev]

±2

23

≥ Maximum rotation angle [deg]

±2

23

≥ 6000

±2

23

16384

Ч

24

6553600

360 Ч 1