Jogging/teaching using pio, 10 jogging/teaching using pio, P l c – IAI America SCON-C User Manual

Page 147

Advertising
background image




129

3.10 Jogging/Teaching Using PIO


If the teaching type is selected, you can jog the actuator via operation from the PLC.
You can also write the current actuator position to the “Position” field of the position table under a specified
position number via operation from the PLC.
If the actuator position is written to a blank “Position” field where no position has yet been defined, the
positioning band and other fields will be automatically populated by their default values set in the applicable
parameters.
Example of use in operation) Move the actuator to the target position by inputting a jog command from the PLC

and write the achieved position to position No. 1.



Controller
































[1]

[1]

[2]

[3]

[4]

[5]

[6]

[7]

[8]

[4]

[6] [8]

[2]

[4]

[5]

[3]

[7]

P


L


C

PIO

Signal name

Command position 1

Operation mode

Manual operation switching

Jog+

Jog-

Current-position write

Current operation mode

Moving

Write completion

Category

Input






Output

Operation mode input ON

Reference flow

Current operation mode output ON

Jog/inching switching input turns
ON, if the manual feed operation is
inching feed.

Move the actuator to the target
position using the Jog+ input or Jog-
input.
Moving output ON

Command position 1 input ON

Current-position write input ON

Write completion output ON

Current-position write input OFF

Advertising