IAI America SCON-C User Manual

Page 30

Advertising
background image




12


[5] Regenerative unit connector

This connector is used to connect an external regenerative resistance unit. The need for regenerative unit
will vary depending on the use condition.


[6] Motor

connector

This connector is used to connect the motor power cable of the actuator.

Motor connector specifications

Item Overview

Description

Connector (cable side) GIC2.5/4-STF-7.52 4-pin, 2-piece connector by Phoenix Contact
Connector name

M1 to 2

Motor connector

Cable size

0.75 mm

2

(AWG18

or equivalent)

Supplied with the actuator

Connected unit

Actuator

1 PE

Protective

grounding

wire

2

Out

U

Motor drive phase U

3

Out

V

Motor drive phase V

Terminal assignments

4

Out

W

Motor drive phase W



[7] Power

connector

This power connector accepts a 100/200-VAC single-phase power supply. The pins are divided into control
power inputs and motor power inputs.

Item Specification

Remarks

Connector
(cable side)

6-pin, 2-piece connector MSTB2.5/6-STF-5.08

connector by Phoenix Contact

Control power: 0.75 mm

2

(AMG18)

Applicable cable
size

Motor power: 2 mm

2

(AMG14)

Recommended stripped wire length:
7 mm

Pin No.

Signal name

1

L1

Motor power AC input

2

L2

Motor power AC input

3

L1C

Control power AC input

4

L2C

Control power AC input

5 NC Not

connected

Terminal
assignments

6 PE Grounding

terminal

Signal names are indicated on the mating connector.


[8] Dedicated pulse-train input mode connector

This connector is used when the controller is to be operated in the pulse-train input mode. Do not connect it
if the controller is to be operated in the positioner mode.


[9] PIO

connector

This connector is used to connect to the host controller (PLC, etc.) via the PIO (parallel input/output) cable.
It consists of a 40-pin flat connector and constitutes a DIO group of 16 inputs and 16 outputs.

Advertising