46

Connecting the Pulse-train Control Cable

Use the pulse-train control cable when the controller is operated in
the pulse-train input mode. It should not be connected when the
controller is operated in the positioner mode.
The pulse-train control cable is optional. (Normally the controller
comes only with a plug and a shell.)







Connecting the Brake Power Input (for Actuator with Brake)

As shown to the left, insert the stripped end of the cable into the
connector and screw in the cable using a screwdriver.
Applicable cable: 0.75 to 1.25 mm
Recommended stripped wire length: 7 mm

















24 VDC

 10%,

1 A max.