51

3.10.4 24 V Power Supply Connector

Connector on

cable side

MC1.5 / 2-STF-3.5 (Phoenix Contact)

Conforming cable

AWG28 to 16

1

0 V

Power supply ground for brake excitation

Terminal assignment

2

24 VIN

+24 V power supply for brake excitation

* It is necessary to supply +24 V to the brake power supply connector of the controller as well.

3.10.5 Brake Release External Switch Connectors 1 and 2

Connection

destination device

Break release switch

Connector on

cable side

XAP-02V-1

(Contact BXA-001T-P0.6) (JST)

Switch rating

30 VDC, minimum current 1.5 mA

1

BKMRL

Brake release switch input

Terminal assignment

2

COM

Brake release switch input power supply output

* If the connector pins 1 and 2 are short circuited, the brake is forcefully released.

3.10.6 Connection

Input +24 V power supply to the 24 V power supply connector of the external brake connection box.






















Controller connection diagram

SCON 400 W or higher

Motor cable

Encoder cable

Actuator

External brake connection box

Encoder cable