 PIO pattern = 5 Solenoid valve mode 2 [3-point type]

Category Signal

name

Signal

abbreviation

Function overview

Rear end move
command

ST0

The actuator will move toward the rear end while this signal remains
at ON level.

Front end move
command

ST1

The actuator will move toward the front end while this signal remains
at ON level.

Intermediate point move
command

ST2

The actuator will move toward the intermediate point while this signal
remains at ON level.

Brake release

BKRL

This signal is used on an actuator equipped with a brake to forcibly
release the brake.

Operating mode

RMOD

This signal switches the operating mode between AUTO and MANU.
(ON: MANU, OFF: AUTO)

Alarm reset

RES

An alarm is reset at a rise edge of this signal.

Input

Servo ON

SON

The servo remains ON while this signal is ON.
The servo remains OFF while this signal is OFF.

Rear end position
detected

LS0

This signal will remain ON while the rear end is recognized.
(This signal is not output in the push & hold mode.)

Front end position
detected

LS1

This signal will remain ON while the front end is recognized. (This
signal is not output in the push & hold mode.)

Intermediate position
detected

LS2

This signal will remain ON while the intermediate point is recognized.
(This signal is not output in the push & hold mode.)

Zone 1

ZONE1

This signal becomes effective after home return. It will turn ON when
the current actuator position enters the range set by the parameters
and remain ON until the actuator exits the range.

Position zone

PZONE

This signal becomes effective when the current actuator position is in
the range specified in the position table, while a position movement
command is input.

Operating mode status

RMDS

A signal indicating the operating mode of AUTO or MANU is output.

Home return completion HEND

This signal is OFF immediately after the power is input, and turns ON
when home return has completed.

Servo-on status

SV

This signal is always output once the servo is turned ON and the
controller is ready to operate.

Emergency stop status

*EMGS

OFF: Emergency stop has been actuated

Alarm *ALM

This signal remains ON in normal conditions of use and turns OFF
when an alarm generates.

Output

Battery alarm

*BALM

This signal is ON when the absolute battery voltage is normal or an
incremental encoder is used.

Take note that incremental position commands are not supported in solenoid valve mode 2 [3-point type].