(9) Feedback pulse pattern

No.

Name

Symbol

Unit

Input range

Default setting

69

Feedback pulse pattern

FBPT

-

0 to 2

0

You can set a desired pattern in which to output feedback pulses.




























If the actuator encoder is not a serial encoder, the
phase-Z signal is output directly.
If the actuator uses a serial encoder, the phase-Z pulse
is output within a mechanical-angle range of

0.5 from

the zero (home) position. Based on the communication
cycle with the encoder, this precision can be assured
when the motor speed is 100 rpm or below.
* The actuator is using a serial encoder if the number

of encoder pulses is 16,384 (pulses/rev).




(10) Feedback-pulse

pattern

polarity

No.

Name

Symbol

Unit

Input range

Default setting

70

Feedback-pulse pattern polarity

FBPT

-

0 to 1

0

You can set a desired polarity to be applied to the feedback pulse pattern.
Setting 0: Positive logic
Setting 1: Negative logic

ZFB

/ZFB

Command pulse-train

pattern

Input terminal

Forward

Reverse

Neg

a

ti

ve lo

gic

P

osit

ive lo

gic

Forward pulse train

Reverse pulse train

A forward pulse train indicates motor revolutions in the forward direction, while a reverse pulse train indicates motor
revolutions in the negative direction.

Pulse train

Sign

Command pulses indicate motor revolutions, while a command sign indicates a rotating direction.

Phase-A/B pulse

train

Phase-A/B x4 pulses with a 90

 phase difference indicate motor revolutions and a rotating direction.

Forward pulse train

Reverse pulse train

Pulse train

Sign

Phase-A/B pulse

train

Setting

2

1

0

2

1

0

AFB

/AFB

BFB

/BFB

AFB

/AFB

BFB

/BFB

AFB

/AFB

BFB

/BFB

AFB

/AFB

BFB

/BFB

AFB

/AFB

BFB

/BFB

AFB

/AFB

BFB

/BFB

Low

Low

High

High