3.9.2

Notes on Incremental Mode

(1) Positioning

mode

If any incremental position number is selected and input and then a start signal is input while positioning is
in progress, the actuator will move to the position corresponding to the target position of the initial command
plus the incremental distance.
(If the incremental distance is a negative value, the actuator will move to the position corresponding to the
target position minus the incremental distance.)
Example) If the start signal for movement to position 2 is input while the actuator is moving to position 1,

the actuator will move to the position 215 mm from the home.

Position table (Field(s) within thick line must be entered.)

























If the start signal for movement to an incremental position number is input multiple times during positioning,
the actuator will move to the position corresponding to the initial position plus the “increment x number of
times the signal was input.”
Example) If the start signal for movement to position 2 is input twice while the actuator is moving to

position 1, the actuator will move to the position 230 mm from the home.













Command position


Start


Position complete




Actuator movement

Speed

Position from home: 230 mm

Distance

Position 1

Position 2

Distance

Position from home: 215 mm

Command position

Start



Position complete




Actuator movement

Speed

Position 1

Position 2

0

1

2

200.00

15.00

=

100.00

20.00

0.10

0.10

0

0

0

1

Position

[mm]

Speed

[mm/ss]

Positioning

band
[mm]

Incremental

Push

[%]

* On the RCM-T teaching pendant, this symbol indicates that the

applicable position is specified in relative coordinates.

Incremental
feed

No.