206

Appendix

4.5 Detail

Connection

Diagram
































(Note) The user must provide the two-paired shielded cable.

If cables other than the recommended brands are connected to [A] and [B], use those with a cable-
sheath outer diameter of 1.35 to 1.60 mm.


Accessories (Optional):
[1] Controller link cable CB-RCB-CTL002 (connector on both ends), length 200 mm
[2] Four-way junction, made by AMP: 5-1473574-4
[3] e-Con connector, made by AMP: 4-1473562-4 (green)
[4] Terminal resistor 220

 (with e-Con connector)

Of the above, [2], [3] and [4] are provided for the same number as the controller link cables. Therefore, not all
units are needed when multiple axes are used.

1

2

SIO converter

Two-paired shielded cable
Recommended brand:
Taiyo Electric Wire & Cable
HK-SB/20276XL
2PX22AWG

Four-way junction (AMP: 5-1473574-4)

A

B

EMG2

EMG1

24V

0V

FG

1

2

3

4

1

2

7

1

2

7

SGA

SGB

GND

Yellow

Orange

Blue

Yellow

Orange

Blue

Housing color: Green

Controller link cable
CB-RCB-CTL002

e-Con connector (AMP: 4-1473562-4)

Controller 1

e-Con connector (AMP: 3-1473562-4)

Housing color: Orange

TB1

TB2

Controller 2

[B]

1

2

3

4

1

2

3

4

1

2

3

4

SGA

SGB

GND

[A]